Test Results – The iEvac® Fire Escape Hood

SEI Cerified

Overall Performance and Protection Capability

Tested by US Army Research,
Development and Engineering Command
Edgewood Chemical Biological Center

Function Test Condition Requirement Result
Overall protection factor Test subjects performing standard NIOSH exercises inside the fit test chamber at Edgewood 2,000 > 80,000
Protection factor inside the hood but outside the nose cup Test subjects performing standard NIOSH exercises inside the fit test chamber at Edgewood 150 > 1,300

Tests to ANSI 110: Physical Properties

Challenge

Test Condition

Duration

Result

Vibration

19 mm at 100 rpm

10,000 cycles

pass

Puncture and tear

100 g striker dropped from 100 mm

Ready to use

pass

Pressure variation

Ambient to 300 mbar below

1,000 cycles

pass

Temperature variation

0°C (32°F) followed by 70°C (158°F)

24 hours each

pass

Flammability

250 mm (9.8 ins)  away from a burner flame of 802°C (1476°F)

One rotation

pass

Molten drip

Molten polypropylene rod drip

Each location

pass

Radiant heat

Within 240 mm (9.5 ins) of heating panel between 527 and 927°C (980 and 1700°F) 

15 secs repeated

pass

Corrosion

Salt spray at 35°C (95°F) then 22°C  (72°F) at 50% RH

48 hours each

pass

Inhalation temperature

CO at 27°C (81°F) and 87%RH

15 mins

pass

Light transmission

Haze of vision area

left and right

pass

Field of vision

Apertometer headform

viewing

pass

Water leakage

Immerse in water at 70°C (158°F) to depth of  600 mm

5 mins

pass

Tests to ANSI 110: Hood Performance Tests

Function Test Condition Duration Requirement Result
Speed of donning Remove from pack and wear properly Less than 30 secs < 30 secs pass
Total inward leakage Test subjects performing standard exercises 2.5 mins < 2% pass
Carbon dioxide build-up Breathing machine 25 cycles per min < 2.5% pass
Breathing resistance Probed headform with breathing machine 30 cycles -2.1    +0.58 pass
Soot particulate Breathing resistance with 200 mg/m³ soot 5 mins <153 mm pass

Tests to ANSI 110:  Gas and Particulate Tests

Challenge Type Concentration ppm Requirement Result
Carbon monoxide Hazardous combustion by-product 3,000 15 mins > 30 mins
Carbon monoxide Hazardous combustion by-product 5,000 15 mins > 30 mins
Hydrogen cyanide Hazardous combustion by-product 400 15 mins > 30 mins
Hydrogen chloride Acid gas toxic industrial chemical 1,000 15 mins > 30 mins
Sulfur dioxide Acid gas toxic industrial chemical 100 15 mins > 30 mins
Cyclohexane Organic vapor toxic industrial chemical 500 15 mins 24 mins
Acrolein Organic vapor toxic industrial chemical 100 15 mins 26 mins
Dioctyl phthalate Particulate aerosol  0.185 micron 200 mg/m³ >95% pass

Additional Gas and Particulate Tests beyond the Requirements of
ANSI 110

Challenge Type Concentration ppm Requirement Result
Carbon monoxide Hazardous combustion by-product 10,000 15 mins > 30 mins
Dioctyl phthalate (DOP) HEPA filtration test for particulates and aerosols 200 mg/m³ >99.97% >99.996%
Ammonia Toxic industrial gas 1,250 15 mins > 60 mins
Formaldehyde Toxic industrial gas 250 15 mins > 60 mins
Phosgene Toxic industrial gas 125 15 mins > 60 mins
Phosphine Toxic industrial gas 150 15 mins > 60 mins
Chlorine Toxic industrial gas 200 15 mins > 60 mins
DMMP Simulant for sarin nerve gas 1,000 15 mins > 60 mins
Hydrogen sulfide Toxic industrial gas 1,000 15 mins >600 mins
Hydrogen sulfide Toxic industrial gas 5,000 15 mins >85 mins
Tear Gas (CN) Irritant toxic chemical 16 15 mins >500 mins
Tear Gas (CS) Irritant toxic chemical 3 15 mins >500 mins